All packagesMedical device integration: Hospital and Comprehensive packagesSee it in the video: an offline core (0:30)Updates, backups and licensing (12:14)
For IT teams: the technical architecture of ClinivaSys inside the hospital
In many hospitals, the IT team inherits systems installed on every device separately, systems that stop when the internet line drops, or systems that need ports open to the outside. The result is a constant maintenance burden, unclear backups and security risks that are hard to control.
ClinivaSys is built on a simple architecture: one Windows server inside the hospital, running the software and a local SQL Server database, and an internal network every device connects to. One installation, one licence activation, and backups and updates from the admin panel, with no reliance on the internet.
Technical architecture
- Server: Windows with a local SQL Server database. It also runs on a virtual server, such as Hyper-V or VMware.
- Devices: computers, iPads and phones open the system in the browser through an internal link, and it can be installed as an app on the home screen. It also runs as a desktop app. Supported browsers: Chrome, Edge and Firefox, and Safari on iPad. A desktop program is available on the server, and an app can be installed from the browser on any device.
- Capacity: devices are unlimited, and one server serves hundreds of concurrent devices without changing the architecture.
- Where the data lives: the database, radiology images, reports and chat attachments all stay inside the facility.
- Clinical AI: runs on the facility’s server with a built-in reference drug library, with no external connection.
Recommended server specifications
| Facility size | Devices | Processor | Memory | Storage |
|---|---|---|---|---|
| Clinic or small center | Dozens of devices | 4 cores | 8 GB | 256 GB SSD |
| Mid-size hospital | A hundred devices or more | 8 cores | 32 GB | 1 TB NVMe |
| Large hospital | Hundreds of devices | 16 cores | 64 GB | 2 TB NVMe (RAID 1) |
Multi-branch support is an upcoming feature of the Comprehensive package.
Network and peripherals
- Network: Cat6 cabling, gigabit switches and enterprise wireless access points for iPads on the wards.
- Printers: thermal printers for patient wristbands and 80 mm queue tickets, and A4 printers for bills and reports.
- Readers: barcode and QR readers, and the phone as a camera for IDs and sample labels.
- Screens: touch screens and iPads, and TV screens for waiting rooms over the local network (Comprehensive package).
Installation and go-live
- One central installation of the software and database on the server, with the tables created automatically.
- The network port is opened in Windows Firewall automatically during installation, with no manual setup.
- The network server is started from inside the software in one click, showing the internal sign-in link. Stopping it is protected by the administrator password.
- The licence is activated once, on the central server.
- The internal link is opened on every device, with nothing installed on it.
A complete technical guide comes with the installation package.
Licensing without the internet
- A signed key tied to the facility’s name and package, verified locally, that won’t work at another facility.
- One activation on the server serves every device.
- Upgrading the package takes a new key that unlocks the locked modules, with no reinstallation.
- A counter warns before expiry in colored stages, with a grace period.
Backup and restore
- Manual backups whenever you need them, and scheduled automatic backups.
.bakfiles saved to a network drive, a USB stick or a local disk.- Data restored from a backup file through the admin screen.
- Automatic backups scheduled at the time and frequency that fit the hospital’s policy.
Updates
- Every update is digitally signed and arrives over the internet, on a USB stick or over the hospital network.
- From the technical support screen: a readiness check, then the update is downloaded, verified and installed safely.
- An audit log, and the option to roll back an update when needed.
Security
- Data-level permissions: by role and for each employee — not by hiding buttons.
- Passwords: stored as a one-way hash that cannot be reversed.
- Accounts and workstations: an account locks after repeated failed sign-ins, a workstation locks when the employee steps away, and passwords can be recovered with no email and no internet.
- Audit log: more than twenty types of events, which can be filtered, exported and printed.
- Break-glass access: a temporary permission for two hours, with the reason recorded and management notified.
- Sensitive operations: a double signature, and the administrator password for deleting, changing permissions and stopping the server.
- No external ports, and no reliance on the internet provider to operate.
- Encrypted connections inside the network: devices talk to the server over HTTPS.
Device integration
Hospital and Comprehensive packages
- Lab analyzers, with their results imported straight into the lab module.
- Monitors and temperature sensors, with a device readiness check from the admin panel.
- Fingerprint terminals of different makes, whose punches reach HR in real time over the network.
- We confirm compatibility with your specific devices before installation. The integration protocol depends on each device.
What needs the internet?
All daily operation runs on the internal network. Only three optional features need a connection:
| Feature | When it needs the internet | Without the internet |
|---|---|---|
| MyHealth | To upload an encrypted copy of the record of a patient who chose to activate it | The original stays on the hospital’s server; for patients who don’t activate it, the record stays internal only |
| Sharing radiology images | When the short cloud link is chosen | A link on the hospital network, or a standalone file on a USB stick |
| WhatsApp messages: appointment reminders, billing notices and the record-sharing link | Only at the moment of sending | Booking and billing carry on uninterrupted |
Specification sheet (PDF)
Technical specification sheet
One A4 page, in Arabic and in English, to hand to hospital management or the supplier before buying the server and network.
- A small architecture diagram
- Server
- Network
- Devices and peripherals
- Security, backups, updates and licensing
- Medical device integration
- Features that use the internet
FAQ
IT team questions
If you don’t find your answer, message us directly.
Does the software need installing on every device?
No. It is installed on the central server only; the other devices open the system in the browser through an internal link.
Does the system require opening ports to the internet?
No. The internal network port is opened in Windows Firewall automatically during installation, and operation needs no external ports.
Where are backups stored?
As .bak files on a network drive, a USB stick or a local disk, restored from the backup file through the admin screen.
What stops if the internet goes down?
Nothing in daily operation. Only three optional features are affected: MyHealth, the cloud link for radiology images, and WhatsApp messages.
Check the architecture yourself before you decide
Book a live demo with our team, or request a 14-day installation on your real server and network.